Modular PSA Oxygen Generator - OXYSWING®
The unique and modular design of the OXYSWING® Modular PSA Oxygen Generator from NOXERIOR (protected by international patents) offers you the following advantages:
 
    - 
    
Unlimited Flexibility
    The best fit solution to any oxygen supply requirement. No risk for excessive oversized systems;
    
    
     
    - 
    
Easy System Adjustment
    In case your oxygen supply conditions will change, simply adjust your OXYSWING® system by varying the number of PSA modules. Just by yourself, no other modifications to the system required;
    
    
     
    - 
    
Lowest Energy Consumption
    Fast pay-back assured. Let OXYSWING® really make you save money;
    
    
     
    - 
    
High Reliability
    First-class components, stainless steel process piping and valve bodies, heavy-duty PLC. It should work. Always.
    
    
     
    - 
    
High Oxygen Discharge Pressure
    Unmatched high oxygen discharge pressure which allows direct oxygen supply to your application without the need for expensive oxygen boosters. Reliable and no additional investments;
    
    
     
    - 
    
Compact
    No other PSA oxygen system on the market with such limited space requirements. Ideal for container solutions;
    
    
     
    - 
    
Easy Fleet Management
    Identical components for the entire model range = limited spare part management, easy maintenance;
    
    
     
    - 
    
Certified Medical Device
    Certified as Class IIB medical device according to the Medical Device Directive 93/42/CE. Besides, the OXYSWING® Modular PSA Oxygen Generators are officially registered at the Ministry of Health (MOH) of various countries all over the world.
     
 
 
Flexibility & System Upgrade
Each OXYSWING® Modular PSA Oxygen Generator can easily be upgraded at any time simply by adding modules or by installing a so-called Dual-Bank in parallel without additional modifications.
A Dual-Bank is a PSA oxygen generator identical to the standard OXYSWING® PSA oxygen generators, but without PLC and power supply, and which will be installed parallel to the standard generator. The Dual Bank will get its power and control signals from the OXYSWING® PSA oxygen generator through a single cable connection (master/slave principle).
One OXYSWING® PSA oxygen generator is able to control up to maximum of two Duals Banks in parallel.
 
Technical Performance - OXYSWING® Modular PSA Oxygen Generators
Feed Air Pressure = 7,0 bar(g) / 100 psig
    
        
            OXYSWING® 
            PSA  
            Generator | 
            Oxygen Production Flow 
            Nm³/h/(scfh) | 
            Length 
            mm/(inch) | 
            Width 
            mm/(inch) | 
            Height 
            mm/(inch) | 
            Weight 
            kg/(lbs) | 
        
        
            | 90 vol. % | 
            93 vol. % | 
            95 vol. % | 
        
    
    
        
            | OS-8 | 
            2,6 
            101 | 
            2,6 
            98 | 
            2,5 
            96 | 
            560 
            22 | 
            735 
            29 | 
            1.674 
            66 | 
            280 
            674 | 
        
        
            | OS-16 | 
            5,3 
            204 | 
            5,2 
            200 | 
            5,1 
            197 | 
            560 
            22 | 
            1.000 
            40 | 
            1.674 
            66 | 
            435 
            1.008 | 
        
        
            | OS-24 | 
            8,0 
            308 | 
            7,8 
            301 | 
            7,6 
            293 | 
            560 
            22 | 
            1.270 
            50 | 
            1.674 
            66 | 
            590 
            1.342 | 
        
        
            | OS-32 | 
            10,6 
            409 | 
            10,3 
            397 | 
            10,1 
            389 | 
            560 
            22 | 
            1.540 
            61 | 
            1.674 
            66 | 
            745 
            1.675 | 
        
        
            | OS-40 | 
            13,1 
            505 | 
            12,8 
            493 | 
            12,5 
            482 | 
            560 
            22 | 
            1.805 
            71 | 
            1.674 
            66 | 
            900 
            2.010 | 
        
        
            | OS-48 | 
            15,6 
            601 | 
            15,1 
            582 | 
            14,9 
            574 | 
            560 
            22 | 
            2.075 
            82 | 
            1.674 
            66 | 
            1.055 
            2.344 | 
        
    
 
 
Oxygen Discharge Pressure =    6,0 bar(g) / 87 psig
Oxygen Dew Point =        -60 °C / -76 F at atmospheric pressure
ATTENTION: The flow rates in the above table can easily be doubled or even tripled in case of combination of one
or two parallel Dual Banks to the Master Unit.